This section lists the electronic scales supported by StarShip and their default (factory) settings.
Scale Type |
Baud Rate |
Parity |
Data Bits |
Stop Bits |
HTRM Command |
CubiScan 100, 110, 125, 150 |
9600 |
None |
8 |
1 |
|
Detecto AS-400D/420D |
1200 |
None |
8 |
1 |
|
Detecto AS-410D |
9600 |
Odd |
7 |
1 |
|
Fairbanks |
9600 |
Odd |
7 |
2 |
|
Mettler Toledo BCA-222 |
9600 |
Even |
7 |
1 |
|
Mettler Toledo PS60 (see below), 8213 |
9600 |
Even |
7 |
1 |
Shift W |
Mettler Toledo PS6L |
9600 |
Even |
7 |
2 |
|
Micro General 1270 |
9600 |
Even |
7 |
1 |
|
MOS 105405 |
2400 |
None |
8 |
1 |
Ctrl B, Shift W, Enter |
NCI 3835 |
4800 |
Even |
7 |
1 |
Shift W, Enter |
NCI RS-7829 |
9600 |
Even |
7 |
1 |
|
Pennsylvania 7X00 |
300 |
Odd |
7 |
1 |
SRP, Enter |
Pennsylvania 7400 |
4800 |
Even |
7 |
1 |
S, R, or P |
Transcell SP Series & SRP 300* |
2400 |
None |
8 |
1 |
Shift P |
Weightronix |
1200 |
Odd |
8 |
1 |
|
Weightronix WI-127 (Choose Toledo 8213) |
9600 |
Even |
7 |
1 |
*In the Device Manager, the flow control will need to be updated to "None".
The Toldeo PS60 Series of scales has multiple different 'modes' it can run in. To make sure it works with StarShip, we'll reset it to the factory defaults.
Note: The two buttons on the PS60 display are the [Select] button (the button with the two arrows going in a circle and the {ZERO} button (has a zero on it)
Apply power to the PS60.
Hold the {SELECT} button down, until [SetuP] appears in the display window.
Press the {SELECT} button about 7 times to advance through the various setup categories until the display shows [END].
Press the {ZERO} button to advance through the various protocols until the word [DEFAULT] appears on the display.
Press the {SELECT} button and the unit will reboot and the protocol selection is complete.
With the DEFAULT protocol selected, this indicator is now set for:
BAUD = 9600
Data Bits = 7
Parity = Even
Stop Bits = 1
Data String = Toledo 8213